Maintenence chedule of desicant air dryer (heatless type)
Compressed air system in factory plays an important role. In order to ensure the stable operation during the manufacturing process, the regulary maintenance is nescessary . However, in fact there are many different problems such as: Air compressors, dusty air dryers, high engine room temperatures, unsecured wind convection ... lead to reduce using time of compressor accessories (air filter, oil filter, oil separator ...). On the other hand, the recommended maintenance in some factories is not seriously followed and there are deviations. To extend the life of the machine as well as compressor components and ensure operate safely Air compressors are very important to maintain regularly and technically correct.Air compressors, dusty air dryers, high engine room temperatures, unsecured wind convection ... lead to reduced use time of compressor accessories (air filter, loc oil, oil separator ...). On the other hand, the maintenance (maintenance) recommended by the manufacturer in some factories is not guaranteed and there are deviated. To lengthen longevity of mạchine as well as compressor components and ensure operator safety , air compressors are very important to maintain regularly and technically .
Period | Checkpoint | Method |
Start up | Pressure indication | All pressure gauges -Drying tower pressure: Same line pressure -Purge pressure: 3.0-3.5 barge -Regeneration tower pressure: Below 0.5 barg |
Solenoid & pneumatic valve | Operation check | |
Back pressure on regeneration tower | Max 0,5 bar. If needed clean the silencer | |
Every 3-4 months | Pre-filter and after filters | Inspect pre-filter and after-filter for dirt, oil and other contaminants. Replace if contaminated. |
Control air filter | Inspect filter element or regulator if needed clean the filter and regulator. | |
Every 6 months |
Calibrate dew point meter (if installed). | Refer to dew point meter owner’s manual. |
Inspect the silencer. | Replace exhaust silencer if back pressure on regeneration exceed 0,5 barg. | |
Inspect solenoid valves. | While dryer is operating, inspect solenoid valves. If leak or malfuntion persists, replace valves. | |
Yearly. | Replace filter elements. | Replace pre-filter and after filters. |
Inspect and replace pneumatic valve. | Inspect valve seating and valve internals, if needed clean or replace the valve. |