Technology

Guide of air filter maintenance

Compressed air system in factory plays an important role. In order to ensure the stable operation during the manufacturing process, the regulary maintenance is nescessary . However, there are many different problems in fact such as: Air compressors, dusty air dryers, high engine room temperatures, unsecured wind convection ... lead to reduce using time of compressor accessories (air filter, oil filter, oil separator ...). On the other hand, the recommended maintenance in some factories is not seriously followed and there are deviations. To extend the life of the machine as well as compressor components and ensure operator safety Air compressors are very important to maintain regularly and technically correct.Air compressors, dusty air dryers, high engine room temperatures, unsecured wind convection ... lead to reduced use time of compressor accessories (air filter, loc oil, oil separator ...). On the other hand, the maintenance (maintenance) recommended by the manufacturer in some factories is not guaranteed and there are deviated. To lengthen longevity of mạchine as well as compressor components and ensure operator safety , air compressors are very important to maintain regularly and technically .
New Hiscrew Oil Next-Hiatchi air compressor

New Hiscrew Oil Next-Hiatchi air compressor

Hitachi compressor oil is produced by Hitachi - one of the Japanese industrial machine brand. Hitachi is a specialized compressor oil for Hitachi air compressor.
Kaeser DSD 202 air compressor  repair and maintenance

Kaeser DSD 202 air compressor repair and maintenance

Kaeser DSD 202 air compressor repair and maintenance

How to deal with some problem of desicant air dryer (heatless type)

How to deal with some problem of desicant air dryer (heatless type)

Swan TS-V air compressor

Swan TS-V airr compressor series is a series of machines using inverter to reduce power consumption and have outstanding features of the Swan TS series. Based on operating phenomena to optimize operation, ensure maximum air volume and minimum power consumption, average electricity savings at: 15% - 30%. Protection and advanced control system improved reliability of safe and enhanced operating performance; Air compressor starts at zero speed, extending the machine's durability.

Troubleshooting of Handsome II

Wednesday - 31/07/2019 03:17

Troubleshooting of Handsome II

Step 1: Check the condition of the LED lamps and find out the cause of      emergency shutdown by refering to the table below:

RUNNING lamp FAULT
  lamp
Fault detected 

Operation of air compressor

OFF  ON

Compressor motor overcurrent or motor coil high temperature.

Emergency shutdown.
OFF Blinking
(1.2 sec./cycle)
Discharge temperature higher than 110ºC(230ºF) or sensor short circuit.
OFF High pitched blinking.
(0,4 sec./cycle)
Sensor failure or poor connector contact.
BLINKING  ON  Dryer failure. Emergency shutdown unless the conditiuous operation is selected.


  Step 2: Eliminate  the cause of the fault.
  Step 3: Press the START button (green) to restart and the FAULT lamp will go  out.
  Caution:

  • The dryer safety machanism is activated when the START and STOP buttons are pressed frequently.
  • Keep 3 minute interval between stop and restart.
  • Countermeasure for motor overcurrent/ motor coil high temperature.

                                                                                            Meter panel:

LED lamps on the meter panel Reset
Power  Running Fault Reset thermal relay
  1.  When excessive curent passed in the motor, the thermal switch trips and the compressor shuts down. Remove the cause of overcurrent and press the thermal relay reset (blue) button. The lamp will go out when the START button (green) is pressed to restart.
  1. Reduced  cooling air volume for the motor may increase motor temperature, activating the motor protector and stopping the compressor. Eliminate the cause, i.e clogged dust filter or the like. Press the START button ( green) to restart, and the FAULT lamp will go out.

When the motor of Handsome II does not starts.

Step 1:  Turn off the earth leakage breaker.
Step 2:  Interchange two of the three phases in the power unit and connect again.
 Step 3:  Return the breaker on and see if the motor starts.

Minh Phu provides maintenance and repair services for air compressors, in addition Minh Phu also provides spare parts for air compressors with high quality at reasonable prices. For further information, please contact (+84)919 23 28 26. Sincerely thank you for your interest and your trust of our service.

Total notes of this article: 0 in 0 rating

Click on stars to rate this article