Technology

Thermostats for air compressor

Thermostat for air compressor has function of regulating the flow of oil onto the compressor cooler to ensure that the oil temperature and air end are always stable in the allowable temperature.
 Schedule Operation  of GRH3  air compressor

 Schedule Operation of GRH3 air compressor

 Schedule Operation of GRH3 air compressor

Desiccants for Absorption air dryer

Activated alumina/Desiccant beads have a white, spherical, non-toxic, odorless, insoluble in water and alcohol. They are able to stand out thermal shock and abrasion with highly mechanical stability and strong absorption (impervious). The particle shape does not expand or crack after absorbing.
Maintanance of Korean Micos 75  air compressor

Maintanance of Korean Micos 75 air compressor

 Air compressor maintenance is the entire job of cleaning the compressor and replacing consumable parts after a certain running time (3000hr or 6000hr) to keep the performance of the machine in the best state. . Checking the machine parameters must be within the allowable limits. Standard maintenance extends the life of the device and does not interrupt the operation of the machine. Minh Phu Machinery and Egineering Services Co., Ltd specializes in supplying spare parts,repairing and maintaining screw air compressors. Below are some photos of maintenance of Micos 75 Air Compressor - Korean Yujin that Minh Phu carried out.
Piston air compressor repair

Piston air compressor repair

Minh Phu Machine and Technical Services Co., Ltd specializes in repairing, maintaining and supplying Piston air compressor parts: air compressor oil, air filter, oil cap, cement ... . Please contact us (Mobile: 0919 23 28 26 - Email: phu82bg@gmail.com) for professional services and competitive price.

Initial start-up

Tuesday - 01/01/2019 23:19

How to operate new  and old air compressor? In order to meet the market needs, factories make diferent manufacturing plans  so the using compressed air need is also various. Beside, Factories often have backup machine( which is for little use) or or companies with seasonal production characteristics, air compressors operate seasonally. For many years of repair and maintenance Air compressors, air dryers we have a lot of trouble cases such as: the machine cannot start, the machine starts up with  load is immediately stopped, when the machine is turned on, the contactor is fired ....  One of the causes of the problem is air compressors is not used for a long time, leading to moisture of electrical equipments and oil filter, separator ... To help customers minimize the problems we would like to sumerize some notes when operating air compressors which is not used for a long time and the operation for newly air compressors.

truc vit fusheng
Sungshin air compressor

1. Operation

 - Notes :

+ Before turn the power ON, make sure if 

 1- Installation

 2- Piping

 3- Electrical wiring have been properly completed.

 + After the installation or  after long unused time ( over a week) , run the machine by way off innitial start-up.  

2. Before  power on

  1. Be sure the power is OFF
  2. Be sure that the grounding is firmly  connected 
  3. Be sure discharge pressure gauge indicates 0.
  4. Detach  the door and remove Starter/control box cover  to ensure DIP, swithes  SW1, SW2 on the printed circuit board are corectly set. 
  5. Make sure that  oil level is around  the upper red line( but lower than the yellow line)

    -  Notes : Oil level lowers after starting.

3. Power on 

  1. Connect the  power  
  2. See if POWER lights glows on the compressor' s instrument panel. 
  3. Digital motor  display the run hours in 10 hour as a unit
  4. Fully open the valve on discharge side 

    Notes : For safey ,the unit will not operate for 5 seconds after the power is ON, even START button is pressed 
4. Operation

    + Make sure stability between about 65 and 100

    + Make sure that, about 20 minutes after starting , the refrigent pressure gauge reads 0,41 to 0,73 MPa. 

       0.73Mpa.

    + Make sure that about 20 minutes after starting the automatic condensate  trap start draining the condensate.

5. Stop

  1. Press STOP button. The compressor stop.
  2. Be sure that the pressure at  DISCHARGE PRESSURE GAUGE  indicates 0 (It returns to 0 for about 1 or 2 minutes afte stop)
  3. Fully close the valve on the discharge side.
  4. Disconnect the power. 
Minh Phu provides maintenance and repair services for air compressors, in addition Minh Phu also provides spare parts for air compressors with high quality at reasonable prices. For further information, please contact (+84)919 23 28 26. Sincerely thank you for your interest and your trust of our service. Air compressor,How to operate air compressor , way to operate air compressor,Initial start-up