When ordering parts, specify the machine type , part name, part numbers to our authorized distributor. Use Kobelco genuine parts when replacing worn parts or repairing. Using non-genuine parts does not guarantee  proper funtions and may result in a failure.

Dyna air compressor

Máy nén khí trục vít Dyna
Common causes and troubles of vacuum pump

Common causes and troubles of vacuum pump

During operation as well as operation of operators '"Malfunction is unavoidable'" Some basic incidents such as: Do not reach vacuum level, pump overload ... With many years of experience, We have successfully repaired many vacuum pumps. The following are some of the reasons why the vacuum pump failures, and some common vulnerabilities with the hope that the operator can identify and take prevention.
Kaeser BSD 72 - Germany Maintenance

Kaeser BSD 72 - Germany Maintenance

KAESER air compressor company was established in 1919 in Corbug - Germany, with over 90 years of experience, the company has developed a system of selling goods and services on a global scale, through representative offices and authorized agents. More than 5000 employees in over 100 different countries and territories, KAESER is considered one of the three most prestigious and successful pneumatic brands in Europe.

Swan srew air compresor CS-AD series

Swan screw series CS-AD series air compressors are designed with direct drive , high-performance operation, large air volume, solid mechanical structure design, durability. The control system automatically diagnoses the trouble of achieving perfection and the highest reliability.

Releplishment of oil air compressor

Wednesday - 19/12/2018 03:50
thay dau may nen khi,Releplishment of oil air compressor
Releplishment of oil air compressor

Peridiodical replenishment is necesssary improving the durability, indicident decrease, stable operation in factory. However, the correct replenishment is vital.  Failure to observe it may cause the hot oil to gush and you maybe burnt ....This articles is useful for you. 

  1. Press STOP button 
  2. Disconnect the power. 
  3. Be sure that the pressure in the the compressor is decreased to the ambient pressure level ( Check if the Presure Gauge indicates 0 Mpa).
  4. Detach the the front door and , when replacing oil , the right enclosure panel. 
  5. Unplug the oil draining pipe on the extended from the oil case. 
  6. Place the oil pan under the oil-draining valve. Open the oil-draining valve . Let the oil totally drained from the oil case. Clse and plug the oil-draining valve. 
  7. Remove the oil cooler and drain the oil in the oil cooler. After oil has been entirely drained , return the oil cooler to its original place. 
  8. Unplug the oil filling port. Fill the genuine synthetic oil into the oil cooler until the oil reaches the yellow line on the oil level gauge.
  9. Be sure that all the plugs are tightly screwed and return the door and the right enclosure panel to their original place. 
  10. Turn on the POWER ON. Press START button and stop it 7 or 8 seconds later. 
  11. Check The oil level with the oil gauge of the oil case. The level will lower because some of it is circulating in pipes or oil cooler.
  12. Confirm that the pressure decrease to the level of the ambient air pressure. Then turn the POWER OFF and replenish some more lubricant into the replenish port. 
  13. After replenishment, fasten the plug on the replenish port securely 

    14. Press START button again to check the oil level when the compressor is at its full load.

CAUSION :

-    If oil is deterriorated as to produce the sludge or to be green, you can not recover the system's function even by the cleaning the oil cooler, oil case and oil piping. You may have to replace the oil cooler and overhaul the entire system( including the air end). 

-   Choose low oil alarm 

-   If ALARM flashes and  E-22 displays on the panel, use HISCREW , be sure that the system's pressure is reduced and disconnected the power, the replenish oil. Restart, run HISCREW then press RESET button.

-   In case ALARM or SHUTDOWN happens, remove its cause before restart the unit.
 